OUTPUTS |
|
High current outputs | 10 x 25A(cont.), 6 x 15A(cont.) with overcurrent and overheating protection. Outputs may be paired to increase continuous current capability. Current and voltage is measured for each output |
Total current output | 150A continuous |
Output current control step | 100mA |
Wipers output | Dedicated output with wiper braking feature |
+5V | Monitored 5V, 500mA output for powering external sensors. |
INPUTS |
|
Analog inputs | 16 inputs, 10 bit resolution, 0-5V (protected), with software selectable 10K Ohm pullup and pulldowns |
CAN Keypads | 2 x Ecumaster keypads (4, 6, 8, 12 keys) |
OTHER |
|
Output state indication | 16 bicolour LEDs |
Accelerometer/Gyroscope | 3D accelerometer with 3D gyroscope for logging and crash detection |
Real time clock | Yes, super capacitor for backup power (up to 3 days) |
CAN BUS |
|
CAN interface | 2 x CAN2.0 A/B |
CAN standard | CAN2.0 A/B – 125, 250, 500, 1000 kbps |
Input/output stream | User defined with bit masking,
up to 100 input messages |
LOGGING* |
|
Logging memory | 256 Mbytes |
Logging speed | Variable, defined per channel, up to 500Hz |
FUNCTIONS |
|
Logical operations | AND, OR, NOT, XOR, >, <, =, >=, <=, !=, isTrue, isFalse, Toggle, Flash, Pulse |
Number of functions | 100 |
Number of operations | 250 |
Update frequency | 500Hz |
Special functions | Wipers, Indicators |
PMU
Preço sobre consulta
ECUMASTER – POWER MANAGEMENT UNIT
Traditionally, fuses and relays served all of those purposes, but they have many disadvantages like complicated wiring looms, sensitivity to vibration/temperature, and difficult diagnostics.
All of these problems can be solved by using intelligent power management units (PMUs). Our newly developed PMU unit is at the forefront of technology. It provides 16 high current outputs (and use of multiple units if more outputs are required).
One of the main advantages of the PMU is continuous current sensing and self-resetting function if the current exceeds a defined level. All output state, voltage and current information can be logged and transmitted via a CAN bus to dash displays to inform drivers of potential problems.
An additional advantage of the PMU system is the ability to define logic for controlling outputs. This is done with data from analog input channels or CAN bus data, and math operations can be defined for each channel. The PMU is also equipped with LED indicators to show the status of each output.
With use of CAN bus keypads or steering wheel switches, all wiring is vastly simplified and lightened.
Two unique features are the inbuilt accelerometer and gyro for logging and “inertia switch” in case of an accident.
Avaliações
Ainda não existem avaliações.